Home›Repair guides›Hercules›Air Cleaner Service

Hercules — Air Cleaner Service

Maintenance · air intake system

From a Hercules service manual covering: D-1500, D-1700, D-2000, D-2300, D-3400, De3000. Check it applies to your exact model before use.

Applies to: Hercules D Series engine

Procedure

  1. Remove filter element from air cleaner.
  2. Clean by blowing compressed air through element from inside out.
  3. Do not apply air closer than 2 inches and do not use more than 50 psi pressure.
  4. Move air jet up and down filter, slowly rotating element, until no more dust is removed.
  5. Replace element after it can no longer be effectively cleaned.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Maximum air pressure 50 psi; keep air nozzle at least 2 inches away.

Source: Hercules service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.