Home›Repair guides›General Motors›Checking/Draining Oil Build-up in the EPR

General Motors 4.3L GM Engine — Checking/Draining Oil Build-up in the EPR

Maintenance · Electronic Pressure Regulator (EPR)

For the General Motors 4.3L GM Engine, from the General Motors service manual.

Before you start

  • Liquid LPG may be present when disconnecting fuel lines; perform in a well ventilated area.

Procedure

  1. Move equipment to a well ventilated area with no external ignition sources.
  2. Start the engine.
  3. With the engine running, close the manual valve.
  4. When engine runs out of fuel, turn key OFF and disconnect the negative battery cable.
  5. Slowly loosen the inlet fitting and disconnect.
  6. Loosen the hose clamp at the outlet hose fitting and remove the hose.
  7. Remove the Retaining Pin in the LPG Temperature Sensor and remove from the EPR.
  8. Remove the three EPR mounting bolts.
  9. Place a small receptacle in the engine compartment.
  10. Rotate EPR 90° so outlet fitting points down and drain the EPR.
  11. Inspect the secondary chamber for large dried particles and remove.
  12. Reinstall EPR with three retaining bolts and tighten to specification.
  13. Reinstall outlet fitting and secure with Retaining pin.
  14. Reconnect electrical connector until it clicks, then pull to confirm locked; connect vacuum line.
  15. Reconnect outlet hose and secure hose clamp.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Tighten EPR retaining bolts to specification; tighten fuel inlet connection to specification

Source: General Motors service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.