Home›Repair guides›Generac›Starting Electric Start Engines

Generac XD5000E — Starting Electric Start Engines

Operation

For the Generac XD5000E, from the Generac owner's manual.

Applies to: Generac XD5000E

Before you start

  • Disconnect electrical loads prior to starting or stopping unit.

Procedure

  1. Turn main breaker switch to Off.
  2. Unplug all electrical loads from the unit's receptacles before starting engine.
  3. Place generator on a level surface.
  4. Turn fuel valve On.
  5. Switch engine control lever to Run.
  6. Squeeze primer bulb 5-10 times until firm; fuel filter should show fuel level at least half full.
  7. Press and hold the Engine Start switch until engine starts; release if it does not start within 5 seconds.
  8. Turn Main Breaker to On.
  9. Select voltage rating with the Voltage Selector.

Full service-parts list: Generac XD5000E →

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.