Home›Repair guides›Generac›Prepare Fuel System for Storage - Electric Start

Generac XD5000E — Prepare Fuel System for Storage - Electric Start

Maintenance · Engine

For the Generac XD5000E, from the Generac owner's manual.

Applies to: Generac XD5000E

Before you start

  • Eye protection is required to avoid spray from spark plug hole when cranking engine.

Procedure

  1. Push and hold decompression lever down.
  2. Push Start/Run/Stop switch to turn the engine for 2 to 3 seconds; do not start engine.
  3. Pull decompression lever up; pull recoil slowly until resistance is felt (closes valves so moisture cannot enter engine cylinder); gently release recoil.
  4. Completely drain fuel tank or completely fill fuel tank to proper level.

Full service-parts list: Generac XD5000E →

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.