Procedure

  1. Remove front contactor assembly as previously shown.
  2. Disconnect the 4 or 2 wires from PCB. For 4 wire coil: remove wires from PCB J1-6, J1-7, J1-8. For 2 wire coil: remove wires from J1-6 and J1-8.
  3. Cut all required zip ties.
  4. Remove two screws from outside of contactor assembly and slide coil off plunger assembly.
  5. Remove trip coil and reverse process for reinstallation.