Generac — Transferring from Utility Power to Generator Power

Operation · Transfer Switch

From a Generac service manual — check it applies to your exact model before use.

Browse Generac generators & specs →

Before you start

  • Never run generator indoors
  • Carbon monoxide hazard
  • Do not exceed generator wattage rating
  • Do not leave unbalanced loads

Procedure

  1. Move generator outdoors at least 5 feet from openings.
  2. Connect male plug of power cord to 125/250V receptacle on generator.
  3. Turn ON circuit breaker for the outlet.
  4. Plug female connector of power cord to power inlet box.
  5. Turn all circuit breakers in transfer switch to OFF position.
  6. Start the generator following generator manual procedures.
  7. Turn ON the GENERATOR MAIN circuit breaker in transfer switch.
  8. Turn ON branch circuit breakers one at a time, alternating phase A and B.
  9. Monitor wattmeters to ensure loads do not exceed generator rating.
  10. Balance loads between phases A and B within 1000 watts.