Before you start

  • Stator leads must be isolated from other components, especially circuit boards, before testing

Procedure

  1. Disconnect and isolate all stator leads
  2. Set VOM to Rx1 scale and zero meter
  3. Test power phase windings AC1-AC2 and SL1-SL2 for resistance
  4. Test power supply winding PS1-PS2 for resistance
  5. Test timing winding TIM1-TIM2 for resistance
  6. Test for short-to-ground using Rx10,000 or Rx1K scale; reading should be infinity
  7. Test for shorts between windings by connecting between different winding leads; reading should be infinity

Tools required

  • VOM (Volt-Ohm-Milliammeter) Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Power phase winding 0.414-0 FridayParts $51.66.465 ohm
  • Power supply winding 0.206-0.227 ohm
  • Timing winding 0.102-0.116 ohm
  • Battery charge winding 0.095-0.108 ohm

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.