Home›Repair guides›Generac›Testing Starter Solenoid

Generac — Testing Starter Solenoid

Testing & diagnosis · Electric Starter

From a Generac service manual covering: EVT-04629-0, EVT-04629-1, EVT-04717-0, EVT-04797-0. Check it applies to your exact model before use.

Browse Generac generators & specs →

Before you start

  • Do not crank starter motor for more than 15 seconds without allowing it to cool at least 2 minutes.

Procedure

  1. Remove positive battery cable from battery, then remove cable from solenoid stud.
  2. Disconnect yellow wire from tab terminal on solenoid; keyswitch OFF.
  3. Set meter to the continuity/diode test position.
  4. Attach one meter test lead to each stud terminal on the solenoid.
  5. Attach jumper lead to battery positive and touch to solenoid tab terminal.
  6. An audible click should be heard and meter should show continuity.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.