Generac — Testing High Temperature Shutdown

Testing & diagnosis · High coolant temperature switch

From a Generac service manual covering: IM100G, IM80G, NP100G, NP80G. Check it applies to your exact model before use.

Browse Generac generators & specs →

Procedure

  1. Disconnect Wire No. 85 from the switch terminal.
  2. Start the engine, let it stabilize and warm up at no-load.
  3. Hold the terminal end of Wire No. 85 into contact with a clean frame ground on the engine.
  4. After a short delay, the engine should shut down.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Switch contacts close at about 225-235° F. (107°-113° C.)

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.