Home›Repair guides›Generac›Test Sub Coil of Stator

Generac — Test Sub Coil of Stator

Testing & diagnosis · Stator sub coil

From a Generac service manual covering: Craftsman 2200i C0010020, Craftsman 3000i C0010030, GP2200, GP3000i, GP3500iO, IQ3500, PRO-3000i INV3000DMN, Premier 2200i INV2200DMN, iQ2000, iQ3500, iX 1600, iX 2000…. Check it applies to your exact model before use.

Applies to: Generac GP3000i, Generac GP3500iO, Generac IQ3500, Generac iX 1600, Generac iX 2000

Before you start

  • Explosion and Fire. Fuel and vapors are extremely flammable and explosive. Add fuel in a well ventilated area. Keep fire and spark away.

Procedure

  1. Stop engine and drain fuel from tank.
  2. Remove electrical box assembly, back window, and upper enclosure half.
  3. Take out C4 connector (do not remove harness of control panel).
  4. Set DMM to measure resistance.
  5. On female side of C4, connect one lead to Pin 1 and the other to Pin 4; measure and record resistance.
  6. If within specified values refer to flow chart; if outside tolerance replace stator.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • iX 800: 0.5 Ohms
  • iX 1600: 0.7 Ohms
  • iX 2000: 0.3 Ohms

Full service-parts list: Generac GP3000i →, Generac GP3500iO →, Generac IQ3500 →, Generac iX 1600 →, Generac iX 2000 →

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.