Procedure
- With solenoid mounted on engine, remove positive battery cable from battery and then remove battery cable from stud terminal on solenoid
- Disconnect yellow wire from tab terminal on solenoid; keyswitch must be in OFF position
- Set digital multimeter to measure ohms/continuity
- Attach one meter test lead to each stud terminal on the solenoid
- Attach one end of jumper lead to positive terminal on battery
- Touch jumper wire to tab terminal on solenoid
- An audible Click should be heard as the solenoid switch closes
- Meter should make a continuous tone (continuity)