Procedure

  1. Insert paper clip into Pin 3 (Wire 55A); red probe to clip, black probe to Stator Lead 11.
  2. Repeat with Pin 6 (Wire 2) and Pin 8 (Wire 55) against Stator Lead 11.
  3. Using two paper clips, test Pin 3 (Wire 55A) to Pin 6 (Wire 2).
  4. Test Pin 3 (Wire 55A) to Pin 8 (Wire 55).
  5. Test Pin 6 (Wire 2) to Pin 8 (Wire 55).
  6. Follow Hi-Pot steps 5a through 5c for each test.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 1500 volts, 1 second maximum

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.