Home›Repair guides›Generac›Test 12 - Test Auto-Manual-Off Switch

Generac — Test 12 - Test Auto-Manual-Off Switch

Testing & diagnosis

From a Generac service manual — check it applies to your exact model before use.

Browse Generac generators & specs →

Procedure

  1. Disconnect wires from the switch terminals to prevent interaction.
  2. Set a VOM to its Rx1 scale and zero the meter.
  3. Connect VOM test probes across the listed switch terminal pairs.
  4. Actuate the switch to Auto, Man and Off and note the VOM readings (continuity/infinity).
  5. Reconnect all wires to the correct switch terminals before proceeding.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Contacts 1&2: continuity only at OFF; 2&3: continuity at MAN/OFF; 4&5: continuity at MAN/OFF; 5&6: continuity at AUTO; 7&8: continuity at MAN/OFF; 8&9: continuity at AUTO

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Generac repair guides →