Generac — Stator Wire Disconnection
For these Generac models: 10 kW Liquid-Cooled, 12.5 kW Liquid-Cooled, 16 kW Liquid-Cooled, 20 kW Liquid-Cooled, 8kW Air-Cooled, II.
Browse Generac generators & specs →
Before you start
- Follow the Instructions carefully. Wire terminal ends must not be touching any part of the equipment
Procedure
- Disconnect Stator a-c output wires 11 and 22 from the Electronic Voltage Regulator terminals
- Disconnect Stator Wire 33 from the 30-amp Breaker (CB1)
- Separate wires 22 and 44 at their junction
- Disconnect Stator Excitation Winding Wires 2 and 6 from the Electronic Voltage Regulator terminals