Home›Repair guides›Generac›Starter Performance Test

Generac — Starter Performance Test

Testing & diagnosis · Electric starter

From a Generac service manual covering: GN-190, GN-191, GN-320, GN-360. Check it applies to your exact model before use.

Browse Generac generators & specs →

Before you start

  • Before removing starter, disconnect the negative battery cable from the battery.

Procedure

  1. Set the meter to read DC amps.
  2. Connect the starter motor, battery and VOM as shown.
  3. Insert the tachometer at the end of the pinion gear and activate the starter motor.
  4. A starter motor in good condition will be within specifications; if not, it should be replaced.

Tools required

  • Digital multimeter (VOM) Amazon
  • Tachometer capable of reading up to 1,500 rpm Amazon
  • Fully charged 12 Volt battery Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Minimum motor rpm = 800
  • Maximum amps = 9
  • At 12 Volts DC

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.