Home›Repair guides›Generac›Space heaters installation - Tubular resistance 75 W and 150 W

Generac — Space heaters installation - Tubular resistance 75 W and 150 W

Installation · space heater (tubular resistance 75 W and 150 W)

From a Generac service manual — check it applies to your exact model before use.

Browse Generac generators & specs →

Before you start

  • Removal of generator back cover shall be performed carefully to avoid dragging between exciter stator and rotor.

Procedure

  1. Disassemble the alternator back fan cover.
  2. Disconnect voltage cables F+ and F- of the regulator inside the terminal box.
  3. Remove alternator back cover to access the exciter stator.
  4. With the cover disassembled, remove both lower fixing screws from the exciter stator.
  5. Fasten the space heater support with the exciter stator screws.
  6. Fasten the rail with the strips in the internal side of the terminal box using a 3.2 mm drill for screw thread M4.
  7. Perform the electric installation of the resistances according to Table 6.2 for the alternator model.
  8. Bind the resistance cables with the F+ and F- cables of the exciter stator.
  9. Pass the cables up to the terminal box and carry out the connection in the terminal strips.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Material 13103726 Amazon eBay consists of 2 resistors (37.5 W 323 Ω each)
  • Material 13105040 Amazon eBay consists of 2 resistors (75 W 161.5 Ω each)
  • Resistors connected to terminals no. 16 and no. 17

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.