Home›Repair guides›Generac›Space heaters installation - Ceramic resistance 55 W

Generac — Space heaters installation - Ceramic resistance 55 W

Installation · space heater (ceramic resistance 55 W)

From a Generac service manual — check it applies to your exact model before use.

Browse Generac generators & specs →

Procedure

  1. Disassemble the alternator back fan cover.
  2. Disconnect cables F+ and F- of the voltage regulator inside the terminal box.
  3. Remove the alternator rotor using the removal device.
  4. Remove the alternator back cover to access the place where the space heaters will be installed.
  5. Carry out the frame drilling and attaching of 04 clamps with rivets.
  6. Attach the ceramic resistance in the metal clamps.
  7. Attach the rail with blocks in the internal part of the terminal box using an M4 drill bit.
  8. Carry out resistances electric installation according to Table 6.1 for the alternator model.
  9. Bind the resistance cables with the generator power cable in the coil head closing.
  10. Pass the cables up to the terminal box and carry out the connection in the terminal strip.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Total heating power 108 W for frames 160 up to 200
  • 215 W for frames 225 up to 250
  • 430 W for frames 280 up to 450

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.