Procedure
- Disassemble the alternator back fan cover.
- Disconnect cables F+ and F- of the voltage regulator inside the terminal box.
- Remove the alternator rotor using the removal device.
- Remove the alternator back cover to access the place where the space heaters will be installed.
- Carry out the frame drilling and attaching of 04 clamps with rivets.
- Attach the ceramic resistance in the metal clamps.
- Attach the rail with blocks in the internal part of the terminal box using an M4 drill bit.
- Carry out resistances electric installation according to Table 6.1 for the alternator model.
- Bind the resistance cables with the generator power cable in the coil head closing.
- Pass the cables up to the terminal box and carry out the connection in the terminal strip.
Tools required
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Total heating power 108 W for frames 160 up to 200
- 215 W for frames 225 up to 250
- 430 W for frames 280 up to 450
Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.