Home›Repair guides›Generac›Service Dual Element and Canister Air Cleaners

Generac — Service Dual Element and Canister Air Cleaners

Maintenance

From a Generac service manual covering: 0D3358, 0D7675, 0D9033, 0D9708, 0E0038, 0E3342, EVT-04174-0, EVT-04198-0, EVT-04629-0, EVT-04629-1, EVT-04630-0, EVT-04712-0…. Check it applies to your exact model before use.

Browse Generac generators & specs →

Before you start

  • NEVER OPERATE ENGINE WITH AIR CLEANER ASSEMBLY OR AIR CLEANER CARTRIDGE REMOVED. FIRE MAY RESULT.

Procedure

  1. Remove and service foam pre-cleaner every 25 hours or every season, whichever occurs first
  2. Service cartridge every 50 hours or every season, whichever occurs first
  3. For canister style cleaners, clean air filter element(s) with compressed air every 50 hours or every season
  4. Replace the air filter element(s) every 500 hours or if damaged
  5. Replace air cleaner gaskets and mounting gaskets that are worn or damaged

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Foam pre-cleaner: 25 hours/season
  • Cartridge: 50 hours/season
  • Canister element: clean 50 hours, replace 500 hours

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.