- NEVER OPERATE ENGINE WITH AIR CLEANER ASSEMBLY OR AIR CLEANER CARTRIDGE REMOVED. FIRE MAY RESULT.
Procedure
- Remove and service foam pre-cleaner every 25 hours or every season, whichever occurs first
- Service cartridge every 50 hours or every season, whichever occurs first
- For canister style cleaners, clean air filter element(s) with compressed air every 50 hours or every season
- Replace the air filter element(s) every 500 hours or if damaged
- Replace air cleaner gaskets and mounting gaskets that are worn or damaged
Tools required
- Compressed air Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Foam pre-cleaner: 25 hours/season
- Cartridge: 50 hours/season
- Canister element: clean 50 hours, replace 500 hours
Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.