Generac — Section 1.1
For these Generac models: CTTS STYLE CONTACTOR ASSEMBLY 600-2600 AMP, CTTS Style CONTACTOR Assembly (100-400 Amp), CTTS Style CONTACTOR Assembly (600-2600 Amp), CTTS Style Contactor Assembly, W Style CONTACTOR Assembly, Wn STYLE CONTACTOR ASSEMBLY 600-2600 AMP, Wn Style CONTACTOR Assembly (100-400 Amp), Wn Style CONTACTOR Assembly (600-2600 Amp).
Applies to: Generac Ctts Style Contactor Assembly 600 2600 Amp, Generac Ctts Style Contactor Assembly, Generac W Style Contactor Assembly, Generac Wn Style Contactor Assembly 600 2600 Amp
Procedure
- 1. Remove front cover.
- 2. Remove top PCB cover (see Figure 3).
- 3. For the purpose of testing, the PCB layout is as follows J1 J2 1 8 2 3 4 5 1 2 3 4 5 6 6 7 looking down)
- 4. If switch is not tripping to neutral, measure the resis tance between J1-6 and J1-8. The resistance of the trip coil should be measured, +/- 7%. If INFINITY is mea
- 5. sured, replace the trip coil. If good, proceed to .
- 5. Measure ohms between AT2 (E2) and PCB J2-5. A resistance of 0.2 ohms should be measured. If INFINITY is measured, replace ATS1 upper limit switch (Part #
- 71345. . If good, measure the resistance between AT1
Source: manual:Generac GTS Trouble Shooting - 0H3949-A2.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.