Generac MTP6000S3 — Pump Rotating Assembly Removal
For the Generac MTP6000S3.
Browse Generac generators & specs →
Before you start
- Power source must be removed before starting.
Procedure
- The power source must be removed prior to removing the rotating assembly.
- Drain the oil in the seal cavity by removing the seal cavity drain plug.
- Clean and replace the drain plug after draining seal cavity of oil.
- Remove the four nuts on the studs of the volute and use the two jack screws to remove the rotating assembly from the volute.
- Separate the rotating assembly by pulling straight away from the pump casing.
Tools required
- Jack screws
Source: manual:49519.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.