Home›Repair guides›Generac›Spark Arrestor Muffler Maintenance

Generac QUIETPACT 75 — Spark Arrestor Muffler Maintenance

Maintenance · Exhaust muffler / spark arrestor

For the Generac QUIETPACT 75, from the Generac owner's manual.

Applies to: Generac QuietPact 75, ISM 1.0L Diesel engine

Before you start

  • Failure to provide and maintain a spark arrestor may be in violation of the law
  • Be sure to reinstall the hex pipe cap tightly

Procedure

  1. Place the unit above a noncombustible surface and ensure the exhaust piping is cool.
  2. Remove the two screws holding the spark arrestor access plate to the rear floor pan.
  3. Remove the spark arrestor access plate and gasket.
  4. Remove the hex pipe cap from the end of the spark arrestor cleanout pipe.
  5. Thread on a 3/8-inch NPT pipe coupling and pipe nipple to extend the cleanout pipe at least 10 inches (250 mm) below the rear floor pan.
  6. Start and run the engine for approximately 15 minutes.
  7. Shut down the engine and allow the piping to cool.
  8. Remove the 3/8-inch NPT coupling and piping.
  9. Apply a graphite-base anti-seize compound to the cleanout pipe threads.
  10. Reinstall the hex pipe cap, access plate, gasket, and two screws.

Tools required

  • 3/8-inch NPT pipe coupling Amazon
  • pipe nipple Amazon
  • graphite-base anti-seize compound Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Run engine approximately 15 minutes

Full service-parts list: Generac QuietPact 75 →

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.