Home›Repair guides›Generac›Spark Arrestor Muffler Cleaning

Generac QUIETPACT 75 — Spark Arrestor Muffler Cleaning

Maintenance · Exhaust muffler

For the Generac QUIETPACT 75, from the Generac owner's manual.

Applies to: Generac QuietPact 75

Before you start

  • Reinstall hex pipe cap tightly; exhaust system is extremely hot.

Procedure

  1. Locate unit above non-combustible surface; ensure exhaust piping is cool.
  2. Remove two screws holding the spark arrestor access plate.
  3. Remove access plate and gasket.
  4. Remove hex pipe cap from end of cleanout pipe.
  5. Thread 3/8 in NPT coupling and nipple extending 10 inches below floor pan.
  6. Start and run engine approximately 15 minutes.
  7. Shut down engine and allow piping to cool.
  8. Remove piping; apply graphite anti-seize; reinstall cap, plate, gasket and screws.

Tools required

  • 3/8 in NPT pipe coupling Amazon
  • 3/8 in NPT pipe nipple Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Extend cleanout pipe at least 10 inches (250 mm) below floor pan
  • Run engine approximately 15 minutes

Full service-parts list: Generac QuietPact 75 →

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.