Generac MTP6000S3 — Pump Inspection Cover and Wear Plate Removal
For the Generac MTP6000S3.
Browse Generac generators & specs →
Before you start
- Only disassemble the pump components required to remedy the problem condition.
- All work must be performed by qualified personnel.
Procedure
- Once the pump has been drained, clean the drain plug and reinstall into inspection cover.
- Remove the four hand lugs and use the two jack screws provided to remove the inspection cover and assembled wear plate.
- Replace the wear plate if it is badly worn or scored.
- To remove the wear plate, remove the four nuts.
- Inspect the inspection cover O-rings and replace if necessary.
Tools required
- Jack screws
Specs & torque values
- Hand Knob (24001101) - 4 On Inspection Cover
- Jack Screw (5/8-11 UNC x 1.75) - 2 On Inspection Cover
- 3/8-16 UNC Nuts
- Lock Washers
- Drain Plug (1 in. NPT Square Head)
Source: manual:49519.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.