Generac 20kW — Over Speed (Shutdown Alarm)
For the Generac 20kW.
Browse Generac generators & specs →
Procedure
- 4320 RPM for three (3) seconds or 4500 RPM immediately. This feature protects the generator from damage by shutting it down if it happens to run faster than the preset limit. This protection also prevents the generator from supplying an output that could potentially damage appliances connected to the generator circuit. Contact the nearest Dealer if this failure occurs. RPM Sense Loss (Shutdown Alarm) During cranking, if the Control Board does not see a valid RPM signal within three (3) seconds, it will shut down and lock out on RPM sense loss. While engine is running, if RPM signal is lost for one (1) second the Control Board will shut the engine down, wait
- 15 seconds, then re-crank the engine. If no RPM signal is detected within the first three (3) seconds of cranking, the Control Board will shut the engine down and latch out on RPM sensor loss. If the RPM signal is detected, the engine will start and run normally. If the RPM signal is subsequently lost again, the Control Board will try one more re-crank attempt before latching out and displaying the RPM sensor failure message. Under-frequency (Shutdown Alarm) After starting, if the generator stays under frequency for more than
- 30 seconds it will shut down. The under-frequency setting is 50 Hz. Internal Fault (Shutdown Alarm) This alarm cannot be cleared, call service dealer. Undervoltage (Shutdown Alarm) If the generator voltage falls below 60% of nominal for more than five (5) seconds, it shuts down. Overvoltage (Shutdown Alarm) If the generator voltage rises above 110% of rating for greater than three (3) seconds, an alarm will be issued and the unit will shut down. If the generator voltage rises above 130% of rating for greater than
- 0.2 seconds, an alarm will be issued and the unit will shut down. Clear Alarm Clear the alarm by setting the AUTO/OFF/MANUAL switch to the OFF position. Press the ENTER key to unlatch any active fault and clear the corresponding alarm message.
- 3.6.2
Source: manual:9f84685f-0bec-42e0-a4e9-5c2c50b4b67b.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.