Home›Repair guides›Generac›Out of Service / Storage Procedure

Generac — Out of Service / Storage Procedure

Maintenance · generator

From a Generac owner's manual — check it applies to your exact model before use.

Browse Generac generators & specs →

Before you start

  • For out of service longer than 90 days if cannot be exercised every 7 days

Procedure

  1. Start engine and warm up
  2. Close fuel shutoff valve, allow unit to shut down
  3. Switch to OFF position
  4. Set main circuit breaker OFF
  5. Set AUTO/OFF/MANUAL to OFF, turn off utility power, remove 7.5A fuse, disconnect battery
  6. Drain oil while warm, refill crankcase
  7. Tag engine with oil viscosity/classification
  8. Remove spark plug, spray fogging agent, reinstall
  9. Remove battery, store in cool dry room on wooden board
  10. Clean generator with mild soap and water

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.