Home›Repair guides›Generac›Out of Service Procedure (storage)

Generac — Out of Service Procedure (storage)

Maintenance · generator

From a Generac owner's manual — check it applies to your exact model before use.

Applies to: Generac EcoGen 6 kW, Generac GT-530 engine, Generac GT-530 engine

Before you start

  • If the generator will be out of service longer than 90 days

Procedure

  1. Start the engine and let it warm up
  2. Close the fuel shutoff valve and allow the unit to shut down
  3. Switch to the OFF position
  4. Set the main circuit breaker to OFF
  5. Set the AUTO/OFF/MANUAL switch to OFF, turn off inverter load center, remove the 7.5A fuse, disconnect battery cables
  6. While engine is warm, drain the oil completely and refill the crankcase; drain and refill the oil reservoir
  7. Attach a tag indicating the oil viscosity and classification
  8. Remove spark plugs, spray fogging agent into the openings, reinstall and tighten spark plugs
  9. Remove the battery and store it in a cool, dry room on a wooden board
  10. Clean and wipe the entire generator

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Full service-parts list: Generac EcoGen 6 kW →

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.