Generac — Operation
For these Generac models: EcoGen 6kW Generator, GT-530.
Applies to: Generac Ecogen 6Kw Generator, Generac Gt 530
Procedure
- 16
- 4.1 FUSE The 7.5 amp fuse on the control panel protects the DC control circuit against overload (Figures 3.1 and 3.2). This fuse is wired in series with the battery output lead to the panel. If this fuse ele- ment has melted open, the engine will not be able to crank or start. Replace this fuse using only an identical 7.5 amp replacement fuse. Whenever the fuse is removed or replaced, the exercise timer needs to be reset.
- 4.2 CHECKING THE ENGINE OIL LEVEL For oil capacities, see the Specifications section. For engine oil recommendations, see the Engine Oil Recommendations section. When low battery levels necessitate running the generator for extended periods of time, the oil level should be checked weekly. To check the engine oil level, proceed as follows (Figures 4.1, 4.2 and 4.3):
- 1. If the generator is running, first turn OFF all associated loads running in the residence. Second, turn the generator's main circuit breaker to the OFF position.
- 2. Move the AUTO/OFF/MANUAL switch to the OFF position.
- 3. Remove the dipstick and wipe it dry with a clean cloth.
- 4. Completely insert the dipstick; then, remove it again. The oil level should be at the dipstick “Full” mark. If necessary, add oil to the “Full” mark only. DO NOT FILL ABOVE THE “FULL” MARK.
- 5. Install the dipstick.
- 6. Reset the AUTO/OFF/MANUAL switch to its original position.
- 7. If the generator was running, first turn the generator's main circuit breaker back to the ON position. Second, turn ON needed loads in the residence. * Repeat steps 3 through 5 for the oil reservoir. n Never operat
Source: manual:696471058185_use.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.