Generac — NOTE:
For these Generac models: 4.6L, CntrlNexus001, V-type.
Applies to: Generac 4 6L, Generac V Type
Procedure
- 9-1 Oper001 Rev. D 05/10 Operation
- 1. Remove the drain hose from its retaining clip or cut the zip-tie securing the oil drain hose.
- 2. Loosen and remove OIL DRAIN HOSE CAP. Drain oil com- pletely into suitable container.
- 3. When all oil has drained, install and tighten OIL DRAIN HOSE CAP and secure drain hose with a new zip-tie, or place the hose in its retaining clip.
- 4. Turn OIL FILTER (Figure 10.1) counterclockwise and remove. Properly dispose of old filter.
- 5. Apply light coating of new engine oil to seal of new oil fil- ter. Install FILTER and tighten by hand only. DO NOT OVER TIGHTEN.
- 6. Remove OIL FILL CAP and add recommended oil. Crankcase oil capacity is listed in the "Specifications" section. n After refilling the crankcase with oil, always check oil level on dipstick. NEVER OPERATE ENGINE WITH OIL BELOW THE DIPSTICK “ADD” MARK.
- 7. Start engine and check for oil leaks.
- 8. Shut OFF engine and wait 10 minutes for the oil to settle down into the oil pan. Recheck oil level on dipstick. DO NOT fill above the dipstick "FULL" mark.
- 9. Dispose of used oil at a proper collection center. COOLING INTAKE/OUTLET Air intake and outlet openings in the generator compartment must be open and unobstructed for continued proper operation. This includes such obstructions as high grass, weeds, brush, leaves and snow. Without sufficient cooling and ventilating air flow, the engine/gen- erator quickly overheats, which causes it to shut down. (See the installation diagram.) The exhaust system parts from this product get extremely hot and remains hot after shutdown. High grass, weeds, brush, leaves, etc. must remain clear of the exhaust. Such materials may ignite and burn from the heat of the exhaust system. INSPECT COOLING SYSTEM Inspect engine cooling system. See the Service Schedule. • Check hoses for damage, deterioration, leaks, etc. Correct any • discrepancies found. Check hose clamps for tightness. • 10-1 Maint030 Rev. A 10/10 Maintenance
Source: manual:97f4ce8b-6f14-4a08-86c8-9fef8303e4fb.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.