Home›Repair guides›Generac›Lowering the Mast

Generac MLT3060K / MLT3060M — Lowering the Mast

Operation · Mast system

For the Generac MLT3060K / MLT3060M, from the Generac owner's manual.

Applies to: Generac MLT3060K, Generac MLT3060M, Mitsubishi L3E-W461ML engine, Kubota D1005-E3BG1-MGM-1 engine

Before you start

  • Lamps become extremely hot during use; allow 10-15 minutes for cooling before handling
  • Contact service dealer if mast hangs up or cable develops slack
  • Do not raise or lower mast while unit is operating

Procedure

  1. Shut down lights and engine
  2. Optionally rotate mast so lights face toward back of unit for transport
  3. Loosen mast rotation knob to rotate mast
  4. Rotate mast until white arrows are aligned and metal stop tabs are touching
  5. Tighten mast rotation knob
  6. Press and hold winch control toggle switch downward to collapse mast to lowest position
  7. Verify electrical cord does not get caught or pinched during lowering

Full service-parts list: Generac MLT3060K →, Generac MLT3060M →, Kubota D1005-E3BG1-MGM-1 engine →

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.