Generac IQ3500 / iQ3500 — Prepare Fuel System/Engine for Storage
Maintenance · engine/fuel system
For the Generac IQ3500 / iQ3500, from the Generac owner's manual.
Applies to: Generac IQ3500, Generac iQ3500 engine
Before you start
- Eye protection required to avoid spray from spark plug hole when cranking engine
Procedure
- Change engine oil.
- Add fuel stabilizer, or drain fuel into an approved container and run engine until it stops.
- Run engine 10-15 minutes to circulate stabilizer if added.
- Remove spark plug.
- Pour a tablespoon (5-10cc) of clean engine oil or fogging agent into cylinder.
- Pull starter recoil several times to distribute oil.
- Install spark plug.
- Pull recoil slowly until resistance is felt, then gently release.
Specs & values
- Adequately treated fuel can be stored up to 24 months