Home›Repair guides›Generac›Installing the Power Inlet Box

Generac — Installing the Power Inlet Box

Installation

From a Generac service manual — check it applies to your exact model before use.

Browse Generac generators & specs →

Procedure

  1. Remove front cover of power inlet box; remove 3 screws securing flanged inlet to bottom plate
  2. Mount power inlet box on exterior of building minimum 24" above grade using four holes provided; seal around anchoring screws
  3. Extend wiring inside box approx 8" from entrance; attach green/bare ground wire to green lead with wire nut
  4. Strip and insert incoming leads into terminals on flanged inlet; insert white wire into nickel-plated screw terminal
  5. Fold wires into enclosure and reattach bottom assembly/inlet with removed screws

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.