Generac — Inspecting the Unit

Maintenance · Light tower

From a Generac owner's manual covering: MLT3060K, MLT3060M, MLT3080KV. Check it applies to your exact model before use.

Applies to: Generac MLT Light Tower, Generac MLT3060K, Generac MLT3060M, Mitsubishi L3E-W461ML engine

Procedure

  1. If stored outside, check for water inside cabinet and generator before each use; dry if wet.
  2. Inspect electrical cords; do not use if insulation cut or worn.
  3. Verify winch cables in good condition and centered on each pulley; do not use kinked or unraveling cable.
  4. Verify mast cable correct.
  5. Verify safety pins for mast lock rod and mast lock bar present and secured with chain; check spring in mast lock bar.
  6. Verify wheel lugs present and properly tightened.
  7. Check coolant level daily in overflow jug; normal level between full and add.
  8. Check oil level daily; do not start if below add mark; add only if below add mark; do not overfill.
  9. Check fuel level.

Full service-parts list: Generac MLT Light Tower →, Generac MLT3060K →, Generac MLT3060M →

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.