HomeRepair guidesImpeller Removal and Inspection

Generac MTP6000S3 — Impeller Removal and Inspection

For the Generac MTP6000S3.

Browse Generac generators & specs →

Before you start

  • Use caution when removing the impeller.

Procedure

  1. With the rotating assembly removed from the pump casing, remove the impeller lock screw and unscrew the impeller from the shaft.
  2. The impeller was installed at the factory using Loctite and so may be fairly difficult to unscrew.
  3. A propane torch can be used to ease loosening the screw if necessary.
  4. Use the impeller removal tool to fix the shaft from rotating, and use a metal bar or piece of wood to rotate the impeller counter-clockwise until it is free of the shaft.
  5. It may be necessary to pound the bar with a hammer to loosen the impeller.
  6. Inspect the impeller and replace it if necessary.

Tools required

  • Impeller removal tool
  • Metal bar
  • Hammer

Specs & torque values

  • Impeller lock screw
  • Loctite adhesive

Source: manual:49519.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.