Generac MTP6000S3 — Impeller Removal and Inspection
For the Generac MTP6000S3.
Browse Generac generators & specs →
Before you start
- Use caution when removing the impeller.
Procedure
- With the rotating assembly removed from the pump casing, remove the impeller lock screw and unscrew the impeller from the shaft.
- The impeller was installed at the factory using Loctite and so may be fairly difficult to unscrew.
- A propane torch can be used to ease loosening the screw if necessary.
- Use the impeller removal tool to fix the shaft from rotating, and use a metal bar or piece of wood to rotate the impeller counter-clockwise until it is free of the shaft.
- It may be necessary to pound the bar with a hammer to loosen the impeller.
- Inspect the impeller and replace it if necessary.
Tools required
- Impeller removal tool
- Metal bar
- Hammer
Specs & torque values
- Impeller lock screw
- Loctite adhesive
Source: manual:49519.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.