Generac GT-990 — Stator Insulation Resistance Test

Testing & diagnosis

For the Generac GT-990, from the Generac service manual.

Browse Generac generators & specs →

Before you start

  • Disconnect and isolate all leads before testing.

Procedure

  1. Disconnect stator output leads 11 and 44 from main line circuit breaker.
  2. Remove stator output leads 22 and 33 from neutral connection and separate.
  3. Disconnect C2 Connector from side of control panel.
  4. Connect terminal ends of Wires 11, 22, 33, and 44 together.
  5. Connect red Hi-Pot test probe to joined leads; black lead to clean frame ground.
  6. Set tester to 1500 volts and apply for one second only.
  7. Observe breakdown lamp.
  8. If lamp comes on, clean and dry stator, then repeat test.
  9. If second test fails, replace stator assembly.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Do not apply voltage longer than 1 second
  • Minimum insulation resistance: rated volts / 1000 + 1 megohm

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.