Home›Repair guides›Generac›Reconfiguring The Fuel System (9, 10, 13, 16, 18 kW V-twin Engines)

Generac GT-990 — Reconfiguring The Fuel System (9, 10, 13, 16, 18 kW V-twin Engines)

Adjustments

For the Generac GT-990, from the Generac service manual.

Browse Generac generators & specs →

Procedure

  1. Open the roof.
  2. For 9/10 kW: loosen clamp and slide back air inlet hose; slide fuel selector out toward back; return hose and tighten clamp.
  3. For 13/16/18 kW: remove air cleaner cover; slide selector lever out toward back; return cover and tighten thumb screws.
  4. Close the roof.
  5. Reverse procedure to convert back to natural gas.

Specs & values

  • Fuel pressure 11 to 14 inches water column for LP

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.