Generac — Governor Initial Adjustment
Adjustments · Mechanical governor
From a Generac service manual covering: GN-190, GN-191, GN-320, GN-360. Check it applies to your exact model before use.
Browse Generac generators & specs →
Before you start
- DO NOT FORCE the idle or main jet when bottoming.
Procedure
- Loosen the GOVERNOR LEVER CLAMP BOLT.
- Hold the GOVERNOR LEVER at its full INCREASE RPM position and rotate the GOVERNOR ARM clockwise as far as it will go.
- Tighten the GOVERNOR LEVER CLAMP BOLT.
- For adjustable carburetors, turn the IDLE JET in until it just bottoms, then back out about 1-1/2 turns.
- For carburetors built prior to 1997 with adjustable main jet, bottom the MAIN JET then back it out about 1-1/2 turns.
Specs & values
- Idle jet back out about 1-1/2 turns
- Main jet back out about 1-1/2 turns
Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.