Home›Repair guides›Generac›Test Starter Motor

Generac GN-724 / GN724 — Test Starter Motor

Testing & diagnosis · Electric starter

For the Generac GN-724 / GN724, from the Generac service manual.

Browse Generac generators & specs →

Before you start

  • DO NOT clamp motor housing in a vise or strike with a steel hammer.

Procedure

  1. Remove starter motor and assemble to test bracket clamped in vise.
  2. Install DC shunt on negative battery terminal.
  3. Connect meter leads to shunt posts.
  4. Activate starter; note RPM and amperes after meter stabilizes.
  5. Good starter: minimum 6500 RPM, maximum 35 amperes.

Tools required

  • Digital multimeter Amazon
  • DC shunt (Briggs & Stratton P/N 19359) Amazon
  • Tachometer (Generac P/N 042223) Amazon
  • Starter test bracket Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Minimum RPM 6500
  • Maximum amperes 35

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.