Home›Repair guides›Generac›Adjust Valves

Generac GN-724 / GN724 — Adjust Valves

Adjustments · Cylinder head and valves

For the Generac GN-724 / GN724, from the Generac service manual.

Browse Generac generators & specs →

Procedure

  1. Set No. 1 cylinder at TDC, compression stroke.
  2. Adjust valves to .005" (0.13 mm) cold.
  3. Torque jam nut and adjusting screw to 60 in. lbs. (6.6 Nm).
  4. Set No. 2 cylinder at TDC and repeat.
  5. Install valve covers with new gaskets; torque to 100 in. lbs. (11.2 Nm).

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • .005" (0.13 mm) cold
  • 60 in. lbs. (6.6 Nm)
  • 100 in. lbs. (11.2 Nm)

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.