Generac — Before Initial Start-Up

For these Generac models: EcoGen 6kW Generator, GT-530.

Applies to: Generac Ecogen 6Kw Generator, Generac Gt 530

Procedure

  1. Set the generator main circuit breaker to its OFF (or OPEN) position.
  2. Set the generator AUTO/OFF/MANUAL switch to the OFF position.
  3. Turn OFF all breakers on the load center of the transfer box (T1 and T2).
  4. Turn OFF all loads connected to the transfer switch terminals T1 and T2.
  5. Check the engine crankcase and reservoir oil level and, if necessary, fill to the dipstick FULL mark with the recommended oil.
  6. Check the fuel supply. Gaseous fuel lines must have been properly purged and leak tested in accordance with applicable fuel-gas codes.
  7. All fuel shutoff valves in the fuel supply lines must be open.