Procedure

  1. Verify utility supply to transfer mechanism is ON
  2. Verify transfer mechanism is in utility position
  3. Prepare standby generator for automatic operation
  4. Turn utility supply circuit breaker to OFF position
  5. Verify generator starts after line interrupt delay
  6. Verify transfer mechanism rotates correctly
  7. Turn utility supply circuit breaker to ON position
  8. Verify return to utility operation after time delay
  9. Confirm system ready for automatic operation

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Frequency: 60-62 Hertz
  • Generator supply voltage: 240-246 VAC
  • Voltage to neutral: 120-123 VAC
  • Maximum load voltage: 115-125 VAC

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.