HomeRepair guidesEnclosure Removal

Generac — Enclosure Removal

For these Generac models: GP2200i, GP3000i, iQ2000, iQ3500, iX1600, iX2000, iX800.

Applies to: Generac Gp3000I, Generac Iq2000, Generac Iq3500, Generac Ix1600, Generac Ix2000, Generac Ix800

Procedure

  1. Remove one (1) flat head screw holding the service access panel.
  2. Remove retaining clip underneath fuel fill cap cover.
  3. Remove four (4) Phillips screws holding control panel to the housing.
  4. Disconnect connectors and ground wires. Remove control panel.
  5. Remove one (1) Phillips screw to remove fuel shutoff knob.
  6. Remove one (1) Phillips screw from recoil access area.
  7. Remove three (3) Phillips screws located on handle (two on iX 800).
  8. Carefully orient assembly so the side with access cover is facing down.
  9. Remove two (2) Phillips bolts on underside of plastic housing.
  10. The side with spark plug access should now be facing up. Remove this half of enclosure.

Source: manual:Generac GP-i GP-iQ iQ and iX Series Inverter Service Manaul 0H5039.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.