Generac — Enclosure Removal
For these Generac models: GP2200i, GP3000i, iQ2000, iQ3500, iX1600, iX2000, iX800.
Applies to: Generac Gp3000I, Generac Iq2000, Generac Iq3500, Generac Ix1600, Generac Ix2000, Generac Ix800
Procedure
- Remove one (1) flat head screw holding the service access panel.
- Remove retaining clip underneath fuel fill cap cover.
- Remove four (4) Phillips screws holding control panel to the housing.
- Disconnect connectors and ground wires. Remove control panel.
- Remove one (1) Phillips screw to remove fuel shutoff knob.
- Remove one (1) Phillips screw from recoil access area.
- Remove three (3) Phillips screws located on handle (two on iX 800).
- Carefully orient assembly so the side with access cover is facing down.
- Remove two (2) Phillips bolts on underside of plastic housing.
- The side with spark plug access should now be facing up. Remove this half of enclosure.
Source: manual:Generac GP-i GP-iQ iQ and iX Series Inverter Service Manaul 0H5039.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.