Procedure
- 8. Test a third diode as follows:
- a.Connect one VOM test lead to the white wire, the
- other test lead to transfer mechanism terminal B1.
- Note the meter reading.
- b. Now, reverse the polarity (reverse the VOM test
- leads). Note the reading.
- c. The diode's forward resistance should be indi-
- cated at one polarity only, “Infinity” at the opposite
- polarity. WHITE .
- 9. Test the fourth bridge rectifier diode as follows: AC GRAY 1 .
- a. Connect first VOM test lead to the red wire, the
- second test lead to terminal B1. Note the meter
Source: manual:83045.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.