Procedure
- 3. Turn OFF all power voltage supplies to the transfer
- switch, -sing whatever means provided (such as the
- "Utility" and "Standby" main fine circuit breakers).
- 4. Disconnect all wires from transfer mechanism ter-
- minal tugs N1, N2, T1, T2, E1, £2.
- 5. Disconnect all wires from transfer mechanism ter-
- minals Al, A2, B1, Be.
- 6. Remove the M5-0.80 capscrews, lockwashers and
- flatwashers that retain the transfer mechanism in the
- enclosure. Then, remove the transfer mechanism.
- Electrical Section Disassembly
- 1. Remove two (2) screws that retain the outer cover to
- the transfer mechanism (Figure 2).
- \a_taah
- | a
- J) BH
- Figure 2. Outer Cover Removal
- 2. Remove four (4) screws that retain the inner cover
- (Figure 3).
- Figure 1. Transfer Mechanism Removal
Source: manual:83045.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.