Generac — and a white (-) wire connect to the coil. Remove these
A Generac service procedure — check it applies to your exact model before use.
Browse Generac generators & specs →
Before you start
- terminal Be. Note the VOM reading.
- polarity). Again, note the meter reading.
Procedure
- 4. Make sure the main contacts are at their "Utility" side,
- Le. the "Utility" arrow is pointing to the green display
- window.
- 5. Set a VOM to its "Rx1" scale and zero the meter. If
- the VOM has a polarity switch, set it to "+DC".
- 6. Test one bridge rectifier diode as follows:
- a. Connect one VOM test lead to red wire terminal
- end and the other test lead to transfer mechanism
- terminal Be. Note the VOM reading.
- b. Now, reverse the test leads (reverse the test
- polarity). Again, note the meter reading.
- c. The forward resistance of a dicde should be indi-
- cated at one polarity only. At the opposite polarity, BLACK
- “infinity” should be indicated.
Source: manual:83045.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.