Procedure
- Withdraw the shaft block device (if installed).
- Withdraw the fan protection screen installed on the flange (if installed).
- Remove the front ring and the coupling discs.
- Position the space rings between the bushing and the coupling discs according to the G Quota adjustment need.
- Assemble the coupling discs according to the G Quota adjustment need.
- Apply chemical lock (Loctite 271) lengthwise in the screw thread.
- Fasten the screws according to the torque value specified in Table 8.1.
Specs & values
- Fixing screws Class 12.9 M12x1.75: 119 to 126
- M10x1.25: 68 to 72
- M12x1.5: 119 to 126
- M20x2.5: 566 to 595