Adjustments · fuel selector

From a Generac service manual — check it applies to your exact model before use.

Browse Generac generators & specs →

Before you start

  • On models with a single cylinder engine, disconnect and remove the battery if installed.

Procedure

  1. The generator was configured for natural gas operation at the factory.
  2. Insert the pin end of the plastic T-handle fuel selector into the hole in the selector tab and pull outward.
  3. Twist the selector clockwise 90 degrees and allow it to return once aligned with the LP position.
  4. On 10 kW units, open the roof, loosen the forward clamp on the air inlet hose, and slide the hose away.
  5. Slide the fuel selector pin on the carburetor out towards the back of the enclosure.
  6. Replace the inlet hose and tighten the clamp securely.
  7. On all other models, remove the air cleaner cover and slide the fuel selector pin from natural gas to LP.

Tools required

  • plastic T-handle fuel selector Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.