Procedure
- The following tools are required to remove the governor shaft bushing, Fig. 10. a. 3/8" drive 5/8" socket. b. 1/4" flat washer, c. 1/4 - 20 screw and nut.
- Assemble tools as shown. a. Tighten nut until bushing is removed, Fig. 11. Fig. 11 - Remove Governor Shaft Bushing
- Check governor gear for burrs or nicks, Fig. 12.
- Check flyweights for damage or wear.
- Check governor cup and thrust washer for damage or wear.
- Check governor gear shaft and bearings for damage or wear.
- Assemble governor shaft to sump to act as a pilot for bush- ing.
- Using Briggs & Stratton Tool P/N 19129, press in bushing until it bottoms, Fig. 13.
- Install lower E-ring. a. Install new oil seal.
- Lubricate thrust washer, governor gear and governor cup wi engine oil and assemble to shaft, Fig. 14. \ ®)
- Install sump with new gasket, Fig. 15. a. Torque screws in sequence shown to 200 in. Ibs. (22.6 Nm).
Tools required
- Fig. 10 - Bushing Removal Tools