Home›Repair guides›Generac›Closing Coil Removal (Wn)

Generac — Closing Coil Removal (Wn)

Repair & overhaul

From a Generac service manual — check it applies to your exact model before use.

Browse Generac generators & specs →

Procedure

  1. Remove cover plate.
  2. Disconnect and label closing coil wiring from PCB J1-1 & J1-2.
  3. Remove all necessary zip ties.
  4. Remove lower closing coil cover plate.
  5. Slide coil off plunger and keeper assembly. Reverse process for reinstallation.
  6. For plunger/spring change only: loosen upper nut from closing coil plunger assembly. Turn plunger assembly counterclockwise from bottom end.
  7. Slide plunger and spring out of bottom of contactor assembly.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.