Home›Repair guides›Generac›Checking Valve Clearance

Generac — Checking Valve Clearance

Maintenance · Engine

From a Generac owner's manual — check it applies to your exact model before use.

Applies to: Generac 7 kW PowerPact

Procedure

  1. Ensure engine is cool, at 60-80 F (16-27 C).
  2. Turn the generator to OFF.
  3. Remove enclosure lid fasteners and lid, then remove the back panel.
  4. Remove spark plug wire and position away from the plug.
  5. Remove spark plug.
  6. Rotate the engine clockwise with a 24 mm socket to bring the piston to TDC of its compression stroke.
  7. Check clearance between the rocker arm and valve stem with a feeler gauge.
  8. If valve clearance is 0.002-0.004 in (0.05-0.1 mm), adjustment is not needed.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • {'item': 'Valve clearance', 'value': '0.002-0.004', 'unit': 'in (0.05-0.1 mm)'}

Full service-parts list: Generac 7 kW PowerPact →

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Generac repair guides →