Home›Repair guides›Generac›Checking Generator Drive Plate Torque

Generac — Checking Generator Drive Plate Torque

Maintenance

From a Generac owner's manual covering: MMG130, MMG175, MMG205. Check it applies to your exact model before use.

Applies to: Generac MMG130, Generac MMG175, Generac MMG205

Procedure

  1. Disconnect battery.
  2. Remove generator fan guard.
  3. Torque each of the drive plate bolts to the specification shown in the table.
  4. Install generator fan guard.
  5. Connect battery.

Specs & values

  • MMG130 36 ft-lbs (49 Nm)
  • MMG175 46 ft-lbs (63 Nm)
  • MMG205 47 ft-lbs (64 Nm)

Full service-parts list: Generac MMG175 →

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.